J.F. Ziegler, W.K. Chu
Journal of Applied Physics
We report measurements of the hydrogen concentrations and densities of amorphous silicon films prepared from glow discharge plasmas of silane. Quantitative results are obtained from the resonant nuclear reaction 15N+1H→12C+4He+γ by counting the emitted γ rays. Mass spectrographic analysis of the gases evolved upon heating are also used to estimate the relative hydrogen concentrations for different preparation conditions. Comparisons are given to previously reported infrared absorption results and to electron microprobe estimates.
J.F. Ziegler, W.K. Chu
Journal of Applied Physics
M.J. Nass, A. Lurio, et al.
Nuclear Instruments and Methods
I. Khubeis, J.F. Ziegler
Nuclear Inst. and Methods in Physics Research, B
J.F. Ziegler
Applied Physics Letters