Claudio Gambella, Jakub Marecek, et al.
Allerton 2019
This paper develops quadratic approximations to the classical models of Darcy-Weisbach and Hazen-Williams for frictional head loss in water pipes. Key elements of the technique are selecting the approximation domain and minimizing the relative error. A comparison for individual pipes over a range of diameter, roughness, and Reynolds number showed that the approximation provides accuracy consistent with the experimental error in the classical equations. Two benchmark water distribution networks are also considered. In these systems, flows and pressures computed using the approximation were consistent with simulations using the classical models. Applications of the approximation include mathematical optimization problems where polynomial expressions are desirable.
Claudio Gambella, Jakub Marecek, et al.
Allerton 2019
Sean A. McKenna, Francesco Fusco, et al.
CCWI 2013
Bradley Eck
EWRI 2016
Bradley Eck, Duygu Kabakci-Zorlu, et al.
Big Data 2022