Ellen J. Yoffa, David Adler
Physical Review B
The impedance of the generalized strip transmission line is computed by variational methods. The use of an upper bound and lower bound approximation yields an average impedance as well as a known maximum error. The one-dielectric microstrip line is treated as a limiting case. Losses are considered. Results include those problems which have been solved elsewhere by conformal mapping techniques as special cases. COPYRIGHT © 1965—THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, INC.